Clinical retrospective study of dental implant removal : do patients who require implant removal desire implant prosthesis again?

2020

Background This study investigated the causes of dental implant removal due to complications, and examined whether patients who had dental implant removal desired re-implant prosthesis treatments. Material and Methods A retrospective case–control study was conducted on patients who had their dental implants removed. We investigated whether the removed dental implant was replaced with other implant prostheses. Age, sex, diabetes, smoking, implant site distribution, reason for implant removal, and blade and root-form implants were categorized as predictive variables. The outcome variable was desire for re-implantation or use of other prosthetic methods after implant removal. A logistic regres…

medicine.medical_treatmentDentistryProsthesisImplant removalOutcome variablemedicineHumansDental Restoration FailureDental implantGeneral DentistryRetrospective StudiesDental ImplantsImplant prosthesisbusiness.industryResearchDental Implantation EndosseousRetrospective cohort study:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyDental Prosthesis DesignCase-Control StudiesUNESCO::CIENCIAS MÉDICASSurgeryImplantDental Prosthesis Implant-SupportedPredictive variablesbusinessImplantologyFollow-Up Studies
researchProduct

In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.

2019

Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …

musculoskeletal diseasesDental ImplantsUltrasound deviceMaterials scienceImplant prosthesisBone Screws030206 dentistryThread (computing)Esthetics Dentalmusculoskeletal systemequipment and suppliescomputer.software_genreExtractor03 medical and health sciencesLoad testingsurgical procedures operative0302 clinical medicineCoronal planeExtraction methodsOral SurgerycomputerFracture typeBiomedical engineeringThe Journal of prosthetic dentistry
researchProduct